Calibrators

Home Search Contact Us Resources Sitemap  

 

Up
Solo
Wed 007 Dose Meter
NetdB Pro-111
NetdB Pro-115
NetdB Pro-117
NetdB Pro-121
NetdB Pro-265
NetdB Pro-280
NetdB Pro-301
NetdB Pro-330
NetdB Pro-371
NetdB Pro-515
NetdB Pro-725
NetdB dBPower
NetdB dBJury
NetdB dBSonic
NetdB Manikin
NetdB DbVision
Calibrators
Symphonie
Tapping Machine
Movipack
Maestro
Orchestra

 

 

 

01dB Acoustic Calibrators

Cal01 / Cal02 Class 1 and Class 2

bullet

Overview

bullet

Specifications

bullet

Picture

acoustic calibrator image cal01

OVERVIEW

The calibrators Cal01 and Cal02 are sound pressure sources dedicated to the on-site calibration of noise measurement systems before and after each measurement session, as defined in most regulations.

Battery operated and lightweight, they comply with the specifications of the standard IEC942 as either class 1 (Cal01) or class 2 (Cal02) acoustic calibrators.

With its quasi-cylindrical shape, the calibrator is comfortable in the hand, and can be easily used. A single push button enables calibration level. The sound output is stopped automatically without user operation.

These devices may be used with either typical sound level meters or PC-based noise measurement systems independently of the weighting network or filter used because of a nominal sound pressure level of 94dB at 1000 Hz.

In higher background levels, the sound level of Cal01 can be amplified by 20dB or it may be attenuated by 20dB if, for example, a calibration signal is to be recorded on a digital tape recorder (DAT) in order to use the complete dynamic range of the tape.

In order to perform an accurate and valuable calibration in presence of extraneous noise sources that vary greatly, the calibrators Cal01 and Cal02 feature an acoustic and electronic control system driven by a micro-processor and controlled by an internal reference microphone.

Cal01 and Cal02 are designed for use with 1 inch microphones and delivered with 1/2 inch microphone adapter.

Top

SPECIFICATIONS

bullet

Acoustic calibrators Class 1 (Cal01) / Class 2 (Cal02) according to IEC 942 (1988)

bullet

PTB approval

bullet

Metrological characteristics *

Reference Cal01 Cal02
Level 94 ± 0.3 dB 94 dB ± 0.5 dB
Amplification +20dB / -20dB -
Stability (better than) ± 0.1 dB ± 0.2 dB
Frequency 1 kHz ± 2 % 1 kHz ± 4 %
Stability (better than) ± 0.5 % ± 1 %
THD less than 3 % 3 %

* for reference conditions (20°C, 1013hPa and 65% RH)

bullet

Calibration certificate provided

bullet

Stabilisation time indicated by red LED

bullet

Emission duration greater than 1 min after stabilisation

bullet

Power supply by a 9V alkaline battery (IEC type 6LR61) for 25-hour continuous operation at 20°C

bullet

Diameter : 43 mm / Height : 90 mm

bullet

Weight : 180 g with battery

bullet

Delivered with a user manual, a 9V alkaline battery, a leather cover (Cal01) and an ½ inch microphone adapter

bullet

Optional adapters for 1/4 and 1/8 inch microphones

Top

PICTURE

Cal01 and Cal02 Acoustic Calibrators

Class 1 and Class 2 acoustic calibrators

Top

 

 

 

 

Back Home Up Next